logo

Contact for quick queries :

info@silicongururubber.com
Phone: + 91 98255 78946

Welding Cable








MAX. DC. RESISTANCE OF CONDUCTOR AT 20C (Ohms/Km)
CONDUCT OR AREA (mm2) NO. & DIA OF WIRES (mm) CURRENT RATING AT MAXIMUM DUTY CYCLE 20% (AMPS) NOMINAL THICKNESS OF COVERING (mm) CALCULATE D OVERALL DIA OF CABLE MAX (mm) APPROXIMATE GROSS WEIGHT Kgms./100 Meters. APPROXIMATE GROSS WEIGHT Kgms./100 Meters.
16 510/0.2 210 2.00 9.5 1.210 31.00
25 800/0.2 279 2.00 11.0 0.780 37.50
35 114/0.2 349 2.00 12.8 0.554 42.50
50 708/0.3 440 2.20 14.6 0.386 60.00
70 999/0.3 555 2.40 17.2 0.272 82.00
95 1351/0.3 669 2.60 2.60 0.206


SALIENT FEATURES

1. SPARK welding cables are manufactured strictly conforming to IS: 9857/90 & through inspection is kept alive to avoid any lapse. Finished product is duly tested in test lab as specified by Indian Standard Bureau i.e. Elongation & current resistance of conducter & tensile strength, elongation, resistance & high voltage test of rubber & the results thus obtained are provided in test certificate with each supply. 2. The main object of the cable i.e. high conductivity & proper flexibility is attained by efficient construction of the whole cable from inner core of the conductor to the outer portion i.e. rubber sheath. 3. It is assured that you will find SPARK welding cables as one of the best product as hoes and sincere skill has been engineered in it.



FLEXIBLES CABLES FOR INSTRUMENTS:

Tower PVC insulated unsheathed single core cable with bright annemaled electrolytic copper conductor 1100 volts grade as per IS 694/1990


Conductor area mm2 Conductor size mm Insulation thickness (Nominal ) mm Insulation thickness (Nominal ) mm Conductor resistance at 20 c Current rating (AMPS)
.5 16/.20 0.60 2.30 37.10 4
.75 24/.20 0.60 2.50 24.10 7
.1 32/.20 0.60 2.70 18.50 11
1.5 30/.25 0.60 3.00 12.70 14
2.5 50/.25 0.70 3.60 7.60 19
4 56/.30 0.80 4.40 4.71 26
6 84/.30 0.80 4.90 3.14 35
10 80/.40 1.00 6.20 1.82 48
16 126/.40 1.00 7.40 1.16 64
25 96/.40 11.20 8.90 .743 80
35 276/.40 1.20 10.00 .527 96
50 396/.40 1.40 11.90 368 130
70 360/.50 1.40 13.60 .259 184
95 475/.50 1.60 15.60 .196 210

Tower PVC insulated and PVC sheathed flexible single & multi core with bright annemaled electrolytic copper conductor 1100 volts grade as per IS 694/1990

Conductor area mm2 Conductor size mm Nominal thickness of sheath & approximate overall diameter
Single core O.D. Two core O.D Three O.D Four core O.d
.5 16/.20 .9 4.2 .9 6.3 .9 6.7 .9 7.2
.75 24/.20 .9 4.4 .9 6.7 .9 7.1 .9 7.7
1 32/.20 .9 4.6 .9 7.1 .9 7.5 .9 8.2
1.5 30/.25 .9 4.9 .9 9 8.2 1.0 7.7 8.9
2.5 50/.25 1.0 5.7 1.0 9.1 1.0 9.7 1.0 10.5
4 56/.30 1.0 6.5 1.0 10.7 1.0 11.4 1.0 12.5
6 84/.30 1.0 7.2 1.1 12.9 1.1 13.7 1.2 16.0
10 80/.40 1.0 8.7 1.2 16.1 1.2 17.1 1.3 19.1
16 126/.40 1.0 10.1 1.3 18.7 1.3 19.9 1.4 22.2
25 196/.40 1.1 12.2 1.4 22.7 1.5 24.3 1.6 27.2
35 276/.40 1.1 13.6 1.5 25.7 1.6 27.6 1.7 30.7
50 396/.40 1.2 16.0 1.6 30.3 1.7 32.4 1.8 36.2

Tower PVC insulated unsheathed single core cable with electrolytic annemaled copper conductor used for power & lighting purpose in house wiring 650/1100/ volts grade confirming to BS 2004/1961



Dia in No. & Dia of conductor Conductor size area Nominal (nominal) Overall dia nominal Current rating
1/18 1/.044 1/1.12 0.981 3.30 5
3/22 3/.029 3/0.737 1.253 3.80 10
3/20 3/.036 3/0.914 1.931 4.20 15
7/22 7/.029 7/0.737 2.99 4.45 20
7/20 7/.036 7/0.914 4.60 5.20 28
7/18 7/.044 7/1.12 6.85 7.85 36
7/16 7/.064 7/1.63 14.60 7.65 53
19/18 19/.044 19/1.63 18.65 8.50 62
19/16 19/.064 19/1.63 39.65 11.55 97
19/14 19/.083 19/2.11 66.45 14.00 160
37/16 37/.064 37/1.63 76.75 14.85 177

Conductor area mm2 Conductor size mm2 Nominal thickness of insulation (mm) Overall nominal Current rating (AMPS)
Copper Aluminum
.1* 1/1.13 .70 2.64 5 - -
1.5 3/0.80 .70 3.25 14 12
2.5 1/1.78 .70 3.50 18 17
2.5 7/0.67 .70 3.73 18 23
4 . 1/2.25 .80 4.00 24 23
4 7/0.85 .80. 4.30 24 29
6 1/2.76 .80. 4.50 31 29
10 ** 1/3.57 1.00 6.20 - - 40
10 7/1.35 1.00 6.40 43 54
16 7/1.70 1.00 7.30 57 69
25 7/2.14 1.20 8.90 74 83
35 7/2.52 1.20 10.10 90 105
50 19/1.78 1.40 11.90 123 125
70 19/2.14 1.40 13.70 177 185
95 19/2.52 1.60/td> 16.00 205


NOTE: * Copper conducter only
** Aluminum conducter only
Current rating at ambient temp. 30 c