MAX. DC. RESISTANCE OF CONDUCTOR AT 20°C (Ohms/Km)
APPROXIMATE GROSS WEIGHT Kgms./100 Meters.
APPROXIMATE GROSS WEIGHT Kgms./100 Meters.
16
510/0.2
210
2.00
9.5
1.210
31.00
25
800/0.2
279
2.00
11.0
0.780
37.50
35
114/0.2
349
2.00
12.8
0.554
42.50
50
708/0.3
440
2.20
14.6
0.386
60.00
70
999/0.3
555
2.40
17.2
0.272
82.00
95
1351/0.3
669
2.60
2.60
0.206
SALIENT FEATURES
1. SPARK welding cables are manufactured strictly conforming to IS: 9857/90 & through
inspection is kept alive to avoid any lapse. Finished product is duly tested in
test lab as specified by Indian Standard Bureau i.e. Elongation & current resistance
of conducter & tensile strength, elongation, resistance & high voltage test of rubber
& the results thus obtained are provided in test certificate with each supply. 2.
The main object of the cable i.e. high conductivity & proper flexibility is attained
by efficient construction of the whole cable from inner core of the conductor to
the outer portion i.e. rubber sheath. 3. It is assured that you will find SPARK
welding cables as one of the best product as hoes and sincere skill has been engineered
in it.
FLEXIBLES CABLES FOR INSTRUMENTS:
Tower PVC insulated unsheathed single core cable with bright annemaled electrolytic
copper conductor 1100 volts grade as per IS 694/1990
Conductor area mm2
Conductor size mm
Insulation thickness (Nominal ) mm
Insulation thickness (Nominal ) mm
Conductor resistance at 20° c
Current rating (AMPS)
.5
16/.20
0.60
2.30
37.10
4
.75
24/.20
0.60
2.50
24.10
7
.1
32/.20
0.60
2.70
18.50
11
1.5
30/.25
0.60
3.00
12.70
14
2.5
50/.25
0.70
3.60
7.60
19
4
56/.30
0.80
4.40
4.71
26
6
84/.30
0.80
4.90
3.14
35
10
80/.40
1.00
6.20
1.82
48
16
126/.40
1.00
7.40
1.16
64
25
96/.40
11.20
8.90
.743
80
35
276/.40
1.20
10.00
.527
96
50
396/.40
1.40
11.90
368
130
70
360/.50
1.40
13.60
.259
184
95
475/.50
1.60
15.60
.196
210
Tower PVC insulated and PVC sheathed flexible single & multi core with bright annemaled
electrolytic copper conductor 1100 volts grade as per IS 694/1990
Conductor area mm2
Conductor size mm
Nominal thickness of sheath & approximate overall diameter
Single core
O.D.
Two core
O.D
Three
O.D
Four core
O.d
.5
16/.20
.9
4.2
.9
6.3
.9
6.7
.9
7.2
.75
24/.20
.9
4.4
.9
6.7
.9
7.1
.9
7.7
1
32/.20
.9
4.6
.9
7.1
.9
7.5
.9
8.2
1.5
30/.25
.9
4.9
.9
9
8.2
1.0
7.7
8.9
2.5
50/.25
1.0
5.7
1.0
9.1
1.0
9.7
1.0
10.5
4
56/.30
1.0
6.5
1.0
10.7
1.0
11.4
1.0
12.5
6
84/.30
1.0
7.2
1.1
12.9
1.1
13.7
1.2
16.0
10
80/.40
1.0
8.7
1.2
16.1
1.2
17.1
1.3
19.1
16
126/.40
1.0
10.1
1.3
18.7
1.3
19.9
1.4
22.2
25
196/.40
1.1
12.2
1.4
22.7
1.5
24.3
1.6
27.2
35
276/.40
1.1
13.6
1.5
25.7
1.6
27.6
1.7
30.7
50
396/.40
1.2
16.0
1.6
30.3
1.7
32.4
1.8
36.2
Tower PVC insulated unsheathed single core cable with electrolytic annemaled copper
conductor used for power & lighting purpose in house wiring 650/1100/ volts grade
confirming to BS 2004/1961
Dia in
No. & Dia of conductor
Conductor size area
Nominal (nominal)
Overall dia nominal
Current rating
1/18
1/.044
1/1.12
0.981
3.30
5
3/22
3/.029
3/0.737
1.253
3.80
10
3/20
3/.036
3/0.914
1.931
4.20
15
7/22
7/.029
7/0.737
2.99
4.45
20
7/20
7/.036
7/0.914
4.60
5.20
28
7/18
7/.044
7/1.12
6.85
7.85
36
7/16
7/.064
7/1.63
14.60
7.65
53
19/18
19/.044
19/1.63
18.65
8.50
62
19/16
19/.064
19/1.63
39.65
11.55
97
19/14
19/.083
19/2.11
66.45
14.00
160
37/16
37/.064
37/1.63
76.75
14.85
177
Conductor area mm2
Conductor size mm2
Nominal thickness of insulation (mm)
Overall nominal
Current rating (AMPS)
Copper
Aluminum
.1*
1/1.13
.70
2.64
5
- -
1.5
3/0.80
.70
3.25
14
12
2.5
1/1.78
.70
3.50
18
17
2.5
7/0.67
.70
3.73
18
23
4 .
1/2.25
.80
4.00
24
23
4
7/0.85
.80.
4.30
24
29
6
1/2.76
.80.
4.50
31
29
10 **
1/3.57
1.00
6.20
- -
40
10
7/1.35
1.00
6.40
43
54
16
7/1.70
1.00
7.30
57
69
25
7/2.14
1.20
8.90
74
83
35
7/2.52
1.20
10.10
90
105
50
19/1.78
1.40
11.90
123
125
70
19/2.14
1.40
13.70
177
185
95
19/2.52
1.60/td>
16.00
205
NOTE: * Copper conducter only
** Aluminum conducter only
Current rating at ambient temp. 30° c